Brookwood Secure Center

August 9, 2017

The potable water for Brookwood Secure Center and Columbia Secure Center are supplied from the nearby Town of Greenport. An existing 50,000-gallon elevated water storage tank on site provides fire and drinking water storage for the two facilities. The tank was constructed in the early 1960s, and inspections indicated it is approaching the end of its useful life. NYSOGS retained Chazen to assist with the design of a replacement water storage tank. Chazen’s design includes replacement of the existing water … Continue reading “Brookwood Secure Center”

South Beach Psychiatric Center

Chazen provided code compliance reviews of the 40,000-square foot Central Services Building constructed through a design-build contract at the South Beach Psychiatric Center. The scope of work included plan review of civil/site, structural, architectural, mechanical, electrical, plumbing, life safety systems and fire protection systems. Chazen worked directly with NYSOGS and the design team on code evaluations and resolution of issues pertaining to codes and regulatory requirements. Construction phase services were also performed including inspection, resolution of code issues, review of … Continue reading “South Beach Psychiatric Center”

NYSDOT Salt Storage Buildings

Salt storage

In conjunction with OGS and NYSDOT, Chazen facilitated the design and construction of seven new salt storage buildings, ranging in capacity from 600-3,000 tons, at existing DOT maintenance facilities in Clinton, Steuben, Suffolk and Rockland Counties. The intent of the projects was to replace deteriorating structures and provide additional salt storage capacity to support maintenance operations. Chazen progressed the projects from initial site investigation through construction, providing topographic survey, geotechnical investigation, structural investigation, site layout and grading, drainage investigation, SEQR … Continue reading “NYSDOT Salt Storage Buildings”

Niagara Falls State Park

Chazen assisted the Office of Parks, Recreation and Historic Preservation in developing a re-imagined parkland design and construction documents for a new 5-acre landscape entrance to Niagara Falls State Park and the main Visitor Center. Key elements include the creation of large sweeping walkways that lead from the City of Niagara Falls into the Park and opening views from the streetscape toward the Visitor Center. Stately stone walls were incorporated to guide visitors though the landscape toward a broad welcome … Continue reading “Niagara Falls State Park”

Office of Children and Family Services

This project includes the relocation of the existing secure perimeter fence at the Industry Secure Center as well as the construction of a six-bay maintenance garage, new access road, grading and drainage. The fence relocation will allow the existing fuel islands and the facility maintenance operations to be outside of the secure perimeter. Field investigations advanced during the design phase included utility markout, soil testing for stormwater design, hazardous materials investigations, survey, SEQR and EAF coordination. Ecological staff also made … Continue reading “Office of Children and Family Services”

Camp Smith Water Tank Replacement

As part of Chazen’s term services agreement with OGS, Chazen was retained to assist with the replacement of the water storage tank at the Camp Smith Training Site in Cortlandt. Chazen provided engineering design support for the replacement of the existing 500,000-gallon water storage tank with an Aquastore® glass-fused-to-steel tank. In addition to the engineering design of the replacement water storage tank, Chazen also developed a hydraulic model of the existing water system at the facility utilizing WaterCAD software. The water … Continue reading “Camp Smith Water Tank Replacement”

Hudson Correctional Facility Evaluation and Replacing of Storm Sewer

Hudson Correctional

The existing storm sewer collection system at the Hudson Correctional Facility is approaching the end of its useful life and requires replacement to function properly. The Facility was constructed in the early 1900s with additions in the 1950s and 1960s with much of the existing storm sewers original to the site. Chazen performed an onsite evaluation of the entire storm sewer network to determine the extent of the replacement required. The system consists of approximately 7,900-LF of pipe ranging from … Continue reading “Hudson Correctional Facility Evaluation and Replacing of Storm Sewer”